Maintenance Free Copper Earthing Electrodes Manufacturer Jaipur

Maintenance Free Copper Earthing Electrodes- Heavy Duty

Maintenance Free Copper Earthing Electrodes 50x3-Heavy

Economic Chemical Earthing Electrodes

Maintenance Free Copper Earthing Electrodes Price (50×3 Heavy ) : 6500/ 

Product Desription: 

3E Solutions is manufacturer and supplier of Maintenance free copper earthing electrode suppliers in Jaipur. Specifications of the Maintenance Free Copper Earthing Electrodes in Heavy duty :

1. Outer Pipe : Length : 3 meter or 10 Feet : GI Pipe : Make -Tata also Jindal.

2. Outer Diameter : 56 mm with Thickness 3.0 mm

3. Terminal – 40×5 mm in Copper 

4. Primary Conductor : Copper pipe dia 25 mm

5 Material between Primary and secondary conductor – Graphite based.

6. Backfill Compound includes 2 Bags of 22 Kg each.

3E Solutions provide best copper earthing electrodes in Jaipur and all over Rajasthan,  which has long life, best electrical performance and stable thermal properties.

Maintenance Free Copper Earthing Electrodes-Commercial Terms and Conditions

1. Prices shall be finalised after knowing the final destination, Quanity and application of the use of the earthing.

2. The Prices, wherever quoted are exclusive of the Taxes / GST. 

3. Freight are Extra as actual.

4. Delivery : We can deliver 140 Pcs per week. The final delivery will be informed in offer only.

5. Payment Terms : 100 % Advance (Upto 140 Pcs). For more, 30% Advance and balance including taxes and transportation, before dispatch against PI.

6. Installation: Only upon confirmation by Labour supplier. Excluded in offer in general. Installation instruction on risks, safety, availability of water as laid in here below to be strictly adhared. We provide earthing installation service in Jaipur and all over Rajasthan including Ajmer, Bhilwara, Neemrana, Bhiwadi, Jodhpur. 

Copper Earthing Electrodes-Installation Instruction

1. Pl premix the backfill compound with water before filling in the augured hole of size not below 8 inch. 

2. Cordinate with site owner/ site incharge for avoiding damage of Telecom/LT/HT electrical cables/Fibre optic lines/ sewerage / water etc lines

 3. Minimum interfering hemisphere of – 2 meter ( pref equal to length of pipe ) shd be mother earth all around the Copper Earthing Electrode for better results. Maintain safe distance from sewerage line / basement and try to avoid loose soil ( refilled ) .

4. The manual digging work is job of unskilled labour. In factory premises where there is risk of high voltage, chemicals, explosives etc, the earthing installation work must be supervised by customer side safety incharge. 

Safety - Precautions

1. Ensure no electrical, water , telecom or sewerage line below the site given for excavation. The manual work by labour to dig the hole involve sharp tools which may cut the cables and damage the pipe lines which may harm or cause civil liability. 

2 Ensure availability of water at the site required for premixing.

3. Pl inform if the mother soil is not available without using machine work like in the case of road, RCC or Pucca floor where we want to install the earthing.

 